STC-3018 Temperature Thermostat panel mount 12V input -Relay 230V 10A

Rating: Not Rated Yet
Availability: in stock 3 item(s) Άμεσα Διαθέσιμο
Product Code:12-00B531

Product Dimensions and Weight

Product Weight: 0.1500KG
14,00 €
Sales price without tax 11,29 €

Description

STC-3018 Temperature Thermostat panel mount 12V input -Relay 230V 10A

Temperature controller for panel mounting.
Ideal for regulating temperature in refrigerators, greenhouses or other electrical equipment.

Setup Configuration Codes:

Code

Function

Range

Default

 

Start / Stop Temperature Control

-55~120°C/-67~248°F

0°C/68°F

P0

Working mode

H

H/C

P1

Diference from defined value

0.2-10

2

P2

High temperature Alarm

-55~120°C/-67~248°F

80°C/176°F

P3

Low temperature Alarm

-55~120°C/-67~248°F

-55°C/-67°F

P4

Offset temperature calibration

-10.0 °c ~ 10.0 °c

0

P5

Output delay

0-60Min

0

P6

Presentation mode

C/F

C

 

Package Content:

  • 1X Temperature Controller
  • 1X NTC 10K Sensor

 

 

Instructions for use:

Press the RST button for 3 s to start the thermostat.

Press again for 3 s to turn it off. When the power is applied, the thermostat switches on automatically.

Pressing the S button for 3 s puts the thermostat in the setting mode, pressing it again flashes the red display and the desired value can be selected with the arrows.

    P0 – Operating mode – H / C, heating / cooling, (factory heating)

    C- Cooling mode

    H-heating mode

    P1 – Hysteresis, 0.2 ° C ~ 10 ° C, (factory 2 ° C) The hysteresis is the difference required when the thermostat reaches the set temperature and stops working again. For example, if we set the heating mode to a temperature of 37-40 degrees, then the difference is 3

hysteresis

    P2 – Upper audible alarm setting –55 ~ 120 ° C, (factory 80 ° C) When the temperature reaches the set value, there will be an alarm action and stop working.

Max temperature alarm

    P3 – Lower audible alarm setting –55 ~ 120 ° C, (factory –55 ° C) low temperature alarm value When the temperature is lower than the set value, there will be an alarm action and stop working.

Low temperature alarm

    P4 – Temperature calibration, comparison and possible adjustment against the actual temperature, –10 ° C ~ 10 ° C, (factory 0 ° C) These functions are used for temperature calibration. If there is a deviation between the detected temperature and the actual temperature, some functional effects can be used. The positive value = measured value + corrected value. For example, we measure the temperature at 25.6 degrees and actually 25.8 degrees. P4 can be used. Set to 0.2 then the final temperature is 25.6+0.2=25.8

Calibration make more precision

    P5 – Time delay, 0 ~ 60 minutes, (factory 0 minutes) Press and hold the RST button to switch the thermostat on / off. his function is generally used for compressor refrigeration. If you purchase some thermostats for the refrigerator freezer, this value must be set. According to the compressor back pressure, the general setting is 3-6 minutes.

Delayed start protect compressor

    P6: C/F conversionIf you want to change to F value, change the unit to F, the unit display light is on. If you want to change it to C value, change the unit to C, the unit display light is not bright. If you want to convert quickly, exit the display, long press You can quickly convert units by adding 3 seconds.

 

Reviews

Last Reviews

There are yet no reviews for this product.
Now please write a (short) review....(min. 100, max. 2000 characters)
First: Rate the product. Please select a rating between 0 (poorest) and 5 stars (best). Rating:
Characters written: